beautypg.com

Service diagnosis, Cswe1 – Scotsman CSWE1 User Manual

Page 13

background image

Service Diagnosis

Problem

Probable Cause

Possible Solution

Water pump will not run

Pump binding in housing

Locate and remove cause of
binding

Open circuit in pump motor

Replace pump

Open circuit to pump

Check wiring

Defective evaporator thermostat

Replace thermostat

Water tank empty

On initial start up, water will not
be in the tank until the evaporator
thermostat stops the freeze cycle.

Normal

Open circuit to water solenoid

Locate and repair wiring

Complete water line restriction

Check for closed shut off valve

Defective evaporator thermostat

Replace

Water valve stuck closed

Replace valve

Open coil on inlet water valve

Replace valve

Water inlet tube from water valve
not directing water to tank

Position outlet end of tube into
water pan

Water inlet screen or filter plugged Clean screen, replace filter

White ice cubes

Water too hard (in excess of 400
ppm)

Water needs treatment

Insufficient water supply in tank

Check for why not enough water

Machine harvests ice too fast -
less than one minute

Taste in ice

Foods stored in bin

Do not put foods in the bin

Packaging material not all
removed

Remove all packaging

Too much noise

Check tubing rattle from contact
with tubes, cabinet, etc.

Reposition tubing

CSWE1

December 1995

Page 13