Service Diagnosis

Problem

Probable Cause

Possible Solution

Excessive water dripping on ice

Water pan overflowing

Check overflow tube for
restrictions. Overflow hose not
inserted in liner drain. Incorrect or
worn flow washer in the inlet
water valve.

Water pan out of position

Install correctly

Water inlet tube from water valve
not inserted in water pan.

Locate tube properly.

Ice jam on cutter grid causing
water to flow into bin

Check cutter grid, check for
mineral build up.

Mineral build up on evaporator

High mineral content in water

Clean the water system

Ice cubes too thin

Evaporator thermostat set for thin
cube

Adjust thickness

Non enough water being
circulated over the evaporator

Check for restriction in water lines

Check water pump and distributor
tube

Evaporator thermostat out of
calibration

Re calibrate or replace

Ice cubes too thick

Evaporator thermostat set at or
beyond maximum thickness

Adjust thickness

Evaporator thermostat out of
calibration

Re calibrate or replace

Overcharge of refrigerant

Recover, evacuate, recharge with
the nameplate charge of R-134a.

Condenser fan does not run

Fan blade stuck against
something

Check fan blade

Motor windings open or bearings
seized.

Replace fan motor

Open circuit in wiring

Check wiring

Defective evaporator thermostat

Replace thermostat