CS55 SERVICE DIAGNOSIS

Low Ice Capacity ..................... Leaky inlet water

Replace valve

............................................ Non-condensable

Replace refrigerant

............................................ gas in the system
............................................ High Head Pressure

Dirty condenser,

............................................

Worn fan motor,

............................................

High air temperature

............................................

High water temperature

............................................ High air temp.

Relocate machine or water line.

............................................ Overcharge

Replace the refrigerant

............................................ Restricted system

Replace the drier and refrigerant

Poor harvest ............................ Too short defrost

Replace cube size control

............................................ Not enough water

Check water supply

............................................ Hot gas valve

Replace

............................................ Inlet water valve pluggedClean or replace
............................................ Air and water temp

Try to change location

............................................ too low

No harvest ............................... Cube size control

Replace

............................................ does not work
............................................ Hot gas valve

Replace

............................................ does not work
............................................ Water inlet valve

Replace

............................................ does not work

Excessive water....................... Drain plugged

Clean drain

in ice storage bin