SYMPTOM

POSSIBLE CAUSE

SUGGESTED CORRECTION

Unit will not run

Blown fuse or breaker

Replace fuse & check for cause

of blown fuse, reset breaker.

Compressor cycles intermittently Low voltage

Check voltage at the supply to

the building.

Check circuit for overloading.

Dirty condenser

Clean the condenser

Air circulation blocked around
unit

Allow sufficient air around unit

Non condensable gas in system

Evacuate and recharge with
nameplate charge

Cubes too small

Cube size control set too warm

Check and adjust for proper

operation

Partially restricted cap tube

Blow charge, evacuate with new

drier, weigh in nameplate charge

Moisture in system

Same as above

Overcharged

Same as above

Undercharged

Same as above, look for a leak.

Cloudy cubes

Spray nozzles plugged

Clean

Needs cleaning

Clean with Scotsman Ice
Machine Cleaner

Irregular size cubes, some
cloudy

Some jets plugged

Clean jets

Shortage of water

Check water supply

Cubes too large

Cube size control set improperly

Check and adjust for proper

operation

Decreased ice capacity

Inefficient compressor

Replace

Low Ice Capacity

Leaky inlet water

Replace valve

Non-condensable gas in the
system

Replace refrigerant

High Head Pressure

Dirty condenser,

Worn fan motor,

High air temperature

High water temperature

High air temp

Relocate machine or water line.

Overcharge

Replace the refrigerant

Restricted system

Replace the drier and refrigerant

SERVICE DIAGNOSIS

CS60

January 1995

Page 14