ADJUSTMENT OF THE BIN THERMOSTAT
CONTROL

Adjust the bin thermostat when the ice maker
turns off too soon (ice level low) or when it turns
off too late (ice storage bin overfills.)

To increase the ice level in the storage bin:

Rotate the bin thermostat adjustment screw

(located under front panel on control box cover)
clockwise one eight turn at a time until the ice
level that the machine maintains is correct.

To decrease the ice level in the storage bin:

Rotate the bin thermostat adjustment screw

counterclockwise one eight turn at a time until
the ice level is correct.

CORRECT SIZE

TOO SMALL, LITTLE OR NO

ICE IN THE CENTER OF THE

TOO BIG, THICK BULGE OF

SOLID ICE ON THE END.

ADJUSTMENT OF THE CUBE SIZE:

Adjust only when cubes are too big or small.

(See the illustration at the right.)

1. Remove front panel, locate knob.

2. To increase the size, turn knob 1/8 turn
clockwise. To make the cubes smaller, turn the
knob 1/8 turn counterclockwise.

3. Observe the size of the cubes in the next two
harvest cycles, if more adjustment is needed,
continue adjustments until the correct size is
obtained.

OPERATION & ADJUSTMENT: OPERATING CHARACTERISTICS

The information shown below covers a wide range of air and water temperatures. It is intended as a
guideline only, and is based on data compiled from NEW CLEAN units. Allow a variation from each end
of the range given.

A. Refrigeration system pressures:

High Side (discharge)

End of Freeze cycle 150 - 160 psig

Harvest cycle 100 - 125 psig

Low side (suction)

End of Freeze cycle 10 - 11 psig

Harvest cycle (maximum) 90 psig

B. Freeze cycle time 20 minutes

C. Defrost cycle time 2- 3 minutes

D. Compressor amps

Freeze cycle 4 to 3.4

Harvest cycle 3.8 to 4.1

CS60

January 1995