beautypg.com

Mdt3f & mdt4f user manual, For the plumber – Scotsman MDT3F12 User Manual

Page 6

background image

For The Plumber

Drains:

The dispenser requires a gravity drain. The pitch
on the drain tubes must be at least ¼ inch fall per
foot of horizontal run. On long horizontal runs, a
vent at the back of the cabinet will improve
draining, and is recommended.

There are two drains to connect: A sink drain, a

7

8

ID plastic tube; and the bin drain, a

5

8

” ID plastic

tube. Install rigid tubing between the machine and
the building drain. Route the drains separately to
the building drain.

Water supply:

Connect cold, potable water to the machine. The
inlet water fitting is a 1/4" male flare located on a
wall inside the cabinet.

A hand valve near the
location is
recommended. A water
filter is also a good
idea.

Follow all local codes.

MDT3F & MDT4F User Manual

November 2008

Page 5

FOLLOW ALL APPLICABLE LOCAL, STATE

AND NATIONAL CODES

Strainer or

Filter

Water Inlet Fitting - 1/4"

Male Flare

(Inside Cabinet)

Sink Drain

Bin and Reservoir

Overflow Drains

Water Supply

Building Drain

(Typical)