beautypg.com

Scotsman F0822 User Manual

Page 16

background image

Service Diagnosis

July 2009

Page 15

N0622L, F0822L, N0922L, F1222L, N1322L, F1522L
Remote Low Side User's Manual

Symptom

Probable Cause

Possible Correction

No ice

No power

Check that ice machine and
condensing unit, if used, both
have power. If power light is out,
check transformer.

Code 3: No water

Restore water

Status light is off

Push and release ON switch

Code 1: No ice sensed

Check for ice flow down chute. if
very slow or no ice being made,
check water inlet tubing for
restriction; check for condensing
unit or refrigeration system
failure

Check auger motor for power, if
no power, check controller
component indicator light. If
there is power to the motor,
check motor windings

Code 2: Auger motor draws too
many amps, controller shuts unit
off.

Check that liquid line valve shuts
off tightly

Check for damage to gear
reducer or auger bearings.

Bin Eyes Blocked light is On

Ice is in the chute.

No ice in the chute. Check
position of sensors, check
sensors for scale build up

Everything is in operation, but no
refrigeration effect

Check liquid line valve

Check condensing unit

Check TXV

Check refrigerant charge

Low ice making capacity

Scale build up

Remove scale from evaporator
and water system

Suction tubing kinked

Check suction tubing

Expansion valve superheat
incorrect

Check superheat

This manual is related to the following products: