Final Check List
After Connections
1. Wash out the bin. If desired, the interior of the
bin could be sanitized.
2. Locate the ice scoop (if supplied) and have it
available for use when needed.
Final Check List:
1. Is the unit located indoors in a controlled
environment?
2. Is the unit located where it can receive adequate
cooling air?
3. Has the correct electrical power been supplied to
the machine?
4. Have all the water supply connections been
made?
5. Have all the drain connections been made?
6. Has the unit been leveled?
7. Have all unpacking materials and tape been
removed?
8. Is the correct switch bezel installed in the trim
strip?
9. Is the water pressure adequate?
10. Have the drain connections been checked for
leaks?
11. Has the bin interior been wiped clean or
sanitized?
12. Have any water filter cartridges been replaced?
13. Have all required kits and adapters been
properly installed?
14, Has the ice machine been properly connected
to the condensing unit or rack?
Control Operation
Use and Operation
Once started, the ice machine will automatically
make ice until the bin or dispenser is full of ice.
When ice level drops, the ice machine will resume
making ice.
Caution: Do not place anything on top of the ice
machine, including the ice scoop. Debris and
moisture from objects on top of the machine can
work their way into the cabinet and cause serious
damage. Damage caused by foreign material is not
covered by warranty.
There are four indicator lights at the front of the
machine that provide information on the condition
of the machine.
Indicator Lights:
•
Power
•
Status
•
Water
•
De-scale & Sanitize
There is front access to two switches – On and Off.
To switch the machine OFF, push and release the
Off button. The machine will shut off at the end of
the next cycle.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
July 2009
Page 9
N0622L, F0822L, N0922L, F1222L, N1322L, F1522L
Remote Low Side User's Manual
Power
Status
No
Water
Time to
Clean
On
Off