Water - Air or Water Cooled

The water supply for ice making must be cold,
potable water. There is a single

3

8

” male flare

potable water connection on the back panel. Water
cooled models also have a

3

8

” FPT inlet connection

for the water cooled condenser. Chilled water can
also be used for this connection.

Backflow

The design of the float valve and reservoir
prevents potable water backflow by means of a
1" air gap between the reservoir's maximum water
level and the float valve water inlet orifice.

Drain

There is one ¾” FPT condensate drain fitting at the
back of the cabinet. Water cooled models also
have a ½” FPT discharge drain connection on the
back panel.

Attach Tubing

Connect the potable water supply to the potable
water fitting,

3

8

” OD copper tubing or the equivalent

is recommended.

Water filtration is recommended. If there is an
existing filter, change the cartridge.

Connect the water cooled water supply to the
condenser inlet.

Note: Do NOT filter water to the water cooled
condenser circuit.

Drains - use rigid tubing: Connect the drain tube to
the condensate drain fitting. Vent the drain.

Connect the water cooled condenser drain tube
to the condenser outlet. Do not vent this drain.

Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser. Be sure to vent the bin drain.

Follow all local and national codes for tubing, traps
and air gaps.

July 2009

Page 7

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote User Manual

Air Cooled or Remote Plumbing

Water Cooled Plumbing

Water Inlet

Condensate

Drain

Building Drain

Condenser
Water Inlet

Potable

Water

Inlet

Condensate

Drain

Condenser
Drain

Drain Vent

Drain Vent

This manual is related to the following products: