Refrigeration - Remote Condenser Models

Remote condenser models have additional
installation needs.

The correct remote condenser fan and coil must be
connected to the ice making head. Liquid and
discharge tubing connections are on the back of
the ice machine cabinet. Pre-charged tubing kits
are available in several lengths to accommodate
most installations. Order the one that just exceeds
the length needed for the installation.

The kit numbers are:

RTE10

RTE25

RTE40

RTE75

There are limits as to how far away from the ice
machine and where the remote condenser can be
located. See page 10 for those limits.

The correct condenser must be used.

Ice Machine
Model

Voltage

Condenser
Model

F0822R,
N0622R

115

ERC111-1

F1222R,
N0922R

208-230

ERC311-32

N1322R

208-230

ERC311-32

Do not reuse condenser coils contaminated with
mineral oil (used with R-502 for example). They will
cause compressor failure and will void the
warranty.

A headmaster is required for all remote condenser
systems. Prior condensers did not have a
headmaster. New head / prior condenser retrofits
can use headmaster kit KPFHM.

Use of non-Scotsman condensers requires
pre-approval from Scotsman Engineering.

July 2009

Page 9

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote User Manual

To Remote
Condenser

Fan Motor

Blue

Ground Wire

Connection

Black

White

Ground

Power

Supply

Wires

Install
Strain
Relief

Install
Strain
Relief

Junction

Box

Cover

Reference: Electrical Detail - Remote

Ground Wire

Connection

Black

White

Ground

Power

Supply

Wires

Install
Strain
Relief

Junction

Box

Cover

Reference: Electrical Detail, air or water cooled.