beautypg.com

Scotsman C2648R User Manual

Page 17

background image

Adjustments

Bridge Thickness - For A Service Tech Only

1.

Push and hold Off till the machine stops.

2.

Remove evaporator cover.

3.

Remove left curtain.

4.

Use a box wrench and rotate the bridge
thickness adjustment screw in 1/8 turn
increments CW to increase bridge thickness.
Rotate CCW to decrease bridge thickness.

Caution: Do not make the bridge too thin or the
machine will not harvest properly. Bridge thickness
adjustments are not covered by warranty.

5.

Return curtain to its normal position.

6.

Push and release the On button. Check next
harvest of ice. Repeat steps 1-6 if needed.

Water purge setting

The water purge is factory set to the automatic
position, suitable for most water conditions. The
setting can be changed to one of 5 manual settings
or left on automatic.

purge
setting

1 -
Minimum

2 -
Moderate

3 - Standard

4 -
Heavy

5 -
Maximum

A - Automatic

Water
Type

RO water
or
equivalent

Factory Setting
for typical
water

High TDS
water

Any with conductivity
not less than 10
microSiemens/cm

To set:

1.

Switch the machine OFF by holding the Off
button in until a number or the letter

A shows

on the display.

2.

Press and release the On button repeatedly
until the number on the display corresponds to
the desired setting.

3.

Press and release the Off switch again to
return to the normal control state.

October 2010

Page 16

C2648
Remote Condenser Models - User Manual

Ice Bridge Thickness Measurement

Too Big

Too Small

Just Right,

Small Cube

1/8 - 3/16"

bridge

Just Right,

Medium Cube

Ice Thickness Sensor