PINOUT
Pinouts
Group Name
Function
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Input Power
Earth
Protection Earth Ground
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
External Trigger
Input
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2A (polarity insensitive)
I2B
Input 2B (polarity insensitive)
Generic Input
-V
Power Reference – Inputs
+V
Power Source – Outputs
-V
Power Reference – Outputs
O1+ Output
1+
O1- Output
1-
O2+ Output
2+
Outputs
O2- Output
2-
O3A
Output 3A (polarity insensitive)
O3B
Output 3B (polarity insensitive)
+V
Power Source – Other I/O
I3A
Input 3A (polarity insensitive)
I4A
Input 4A (polarity insensitive)
-V
Power Reference – Other I/O
I34B
Input 3B and 4B (common) (polarity insensitive)
Other I/O
I34B
Input 3B and 4B (common) (polarity insensitive)
TX
Auxiliary Interface TX
RX Auxiliary
Interface
RX
Auxiliary
Interface
SGND Auxiliary
Interface
Reference
REF Network
Reference
ID+
ID-NET™ network +
ID-NET™
ID- ID-NET™
network
-
Network
Shield
Network Cable Shield
RS232 RS485FD
RS485HD
TX
TX+
RTX+
RTS
TX-
RTX-
RX
*RX+
CTS
*RX-
Main Interface
SGND
SGND
SGND
The input power signals Vdc, GND and Earth as well as the network signals REF, ID+, ID- and Shield; and
RTX+, RTX- and SGND are repeated to facilitate system cabling. In this way the power and network busses can
enter and exit the CBX500 from different spring clamps but be physically connected together.
* Do not leave floating, see Reading Device Reference Manual for connection details.
NOTE
To avoid electromagnetic interference:
- Connect CBX500 Protection Earth (Earth) to a good earth ground.
- Connect the reading device chassis to earth ground through the jumper, (default setting, see
Figure 8).
- Connect the Network Cable Shield (Shield) to Filtered Earth through the jumper (default
setting, see Figure 7).
CAUTION
Do not connect to the Main Interface spring clamp terminals if using Host Interface Modules
(Fieldbus).