background image

54

55

CHAPTER 7 ALARMS

PICTURE 6-11

RUNNING PTZ FUNCTIONS

Clicking on the Page Switch button in the PTZ Control Panel (

Picture 6-5

) will switch to a

new window (

Picture 6-11

) which allows you to activate the functions created above as well

as the Auto Pan and Flip functions.

Enter the number of the function you wish to
activate and select the function button to run
that function.

In addition, there are other functions that can
be engaged in this window.

AutoPan - This will cause the camera to

automatically rotate.

Flip - Most PTZ cameras have a mechanical

stop which will prevent the camera
from rotating a full 360°. If the camera
is tracking someone or some thing
and it reaches this stop, pressing Flip
will bring the camera around the other
direction to continue tracking. Some
PTZ cameras have “E-flip” which will
do this automatically.

Page Switch - returns you to the PTZ
Control Panel
(

Picture 6-5

)

Reset - This ends the currently running

function.

NO C

1

NO C

2

1 2 3 4

5 6 7 8

A B

CNTRL

12V

ALARM IN

This DVR features connections for external alarms – both input and output. When an event is
detected the system can notify local users or send notification to a monitoring service. At the
same time, the system can accept signals from motion detectors, smoke detectors or other
alarms and begin recording based on that input and your settings.
You will need to have the manual for your alarm(s) handy to ensure the proper settings within
the DVR.

ALARMS

CHAPTER 7

7.1 ALARM INPUT

When attaching alarms, the following criteria
must be met:
1. The alarm input must be grounded.
2. A grounding signal is required for the

alarm input

3. When connecting the DVR to another

device - including another DVR - through
the alarm input, a relay should be used to
separate them.

Parameter

Grounding Alarm

Ground line

Alarm Input

1, 2, …, 8 becomes valid in low voltage.

1-NO C
2-NO C

Two NO activation outputs.

CTRL 12V

Controls the power output
You need to close the device power to
cancel the alarm.

PICTURE 7-1