6
REMKO
ELECTRIC BOOSTER HEATER WITH EMERGENCY
HEATING MODE FOR HEAT PUMP INDOOR UNITS
1. Remove the housing panels (Fig. 1).
2. The bottom housing panel is folded
down or removed.
3. The front of the housing is secured
with two screws, and can be
removed in an upwards direction
after undoing the screws.
4. After removing two screws,
the cover of the switch cabinet
can be folded down and
removed.
5. After undoing the screws, the
switch cabinet can be folded down
to facilitate installation.
6. Remove the lid by undoing
the 4 screws.
7. Shut-off valves must be closed.
8. Empty the indoor unit on the
water side (drain cock).
9. Remove the 2" blanking plug
from the heating cylinder
(Fig. 2).
10. Use hemp to seal the electric
heating coil.
Installing the 9 kW emergency heating coil in the CMF indoor unit
1 Removing the housing panel
2 Removing the 2" blanking plug
3 Screwing in the electric heating coil