Before commissioning, Technical data – REMKO Elektric Booster Heater with Emergency Heating Switch User Manual
Page 11
11
Before commissioning
Before the system is connected to the
mains electricity supply and put into
service for the first time, it is vital that it
is filled with water.
Adjust the thermostat control to the
desired water temperature.
Please note the instructions on page 4.
Check that the STB has been reset.
Switch on emergency heating mode and
check that all heating coils are being
supplied with voltage.
During the heating process, the expan-
sion water generated in the internal boiler
should drip out of the safety valve if there
!
ATTENTION
The warm water drain pipe as well
as parts of the safety equipment
may become hot.
We reserve the right to modify the dimensions and constructional design as part of the ongoing
technical development process.
Technical data
Series
Electric booster heater
Installation location
To be incorporated into the indoor unit
Operating limits
°C
+40 to +85
Power supply
V/Hz
400/3~/50
Max. operating pressure
bar
10
Electr. rated power
consumption
kW
3 / 6 / 9 kW (3 kW per setting)
Number of elements
3
Installation length
mm
400
Total length
580
Thread diameter
mm
2“
Serial number
768W...
EDP no.
260064
is a pressure-tight connection, and out
of the overflow mixer tap if there is an
unpressurised connection (see also P. 5).