beautypg.com

Technical data – REMKO HTK 100 User Manual

Page 18

background image

18

Technical Data

Model

HTK 100

HTK 160

rated heat power max.

kW

88

160

rated heat output

kW

80

146

rated air output

1)

m³/h

6,260

12.780

pressure,

max. complete

Pa

480

680

fuel

heating oil or diesel (DIN 51603)

fuel consumption, max.

L/h

8,6

15,7

oil nozzle (Danfoss)

2)

USG

1,75 / 60°S

3,00 / 80°S

pump pressure, approx.

2)

bar

12,5

13,5

waste gas emissions, max.

%

9

9

waste gas volume, approx.

kg/h

138

250

furnace resistance, approx.

Pa

100

110

required chimney draught

Pa

0

0

electrical connection

V/Hz

400 / 3~N / 50

power consumption max.

kW

2,45

4,4

rated current max.

A

6,6

10

power consumption

(

oil preheater

)

W

30

30

fuse protection (supplied)

A

16

16

increase of temperature (

t

)

K

42

41

sound pressure level L

pA

1m

3)

dB (A)

62

66

air outlet Ø

mm

400

500

waste gas connection Ø

mm

150

200

length, total

mm

1.905

2.380

width, total

mm

660

785

height, total

mm

1.070

1,245

weight with burner

kg

240

385

We reserve the right to make changes to dimensions and design in the interest of technical progress.

1)

t

45K / 1,2 kg/m³)

2) The mentioned nozzle-sizes and pump pressures were determined on the basis of adjustment tests on test units. The oil throughput had been
measured out. The specifications serve only as guidelines due to product-specific differences in nozzle and pressure tolerances and oil temperature.
3) Noise measuring (with hose / and without burner)

This manual is related to the following products: