Page 15

background image

The suction pipeand /
or liquid separator in the
compressor have iced up

Heating output increases

Is the outdoor component

running continuously?

Reduce the heating load. If

necessary, install additional units /

isolate the iced up components

Troubleshooting and customer service

The equipment and components are manufactured using state-of-the-art production methods and tested several
times to verify their correct function. If malfunctions should occur, please check the functions as detailed in the
list below. Please inform your dealer if the unit is still not working correctly after all the functional checks have
been performed!

Fault

possible cause

Checks

Remedial measures

The unit does not start or
switches itself off

Power outage, undervoltage, defective

mains fuse / main circuit breaker

switched off

Are all electrical installations

functioning correctly?

Check the voltage and if necessary

wait for it to come back on

Damaged mains cable

Are all electrical installations

functioning correctly?

Repair by specialist

Waiting time after switch-on too short Have approx. 5 minutes

elapsed since the restart?

Schedule longer waiting times

Temperature outside operating

temperature range

Are the fans in the indoor unit

and outside component working

correctly?

Take into account the temperature

range for the indoor unit and

outside component

Overvoltages caused by thunder

storms

Has there recently been lightning?

Switch off the mains protection

and switch it back on /have it

checked by a specialist

Fault in external condensation pump

Did the pump shut down due to

a fault?

Check and if necessary clean the

pump

The unit does not respond
to the remote control.

Transmission distance too far / receiver

affected by interference

Does the indoor unit beep when

pressing a button?

Reduce the distance to less than 6

m or change position

Defective remote control

Is the unit running in manual mode?

Replace the remote control

Receiver&transmitter unit exposed to

excessive solar radiation

Does it function correctly in the

shade?

Place the receiver&transmitter unit

in the shade

Electromagnetic fields are interfering

with transmission

Does it function when switching off

possible sources of interference?

Signal is not transmitted when

interference sources are operational

Button in remote control jammed /

two buttons pressed at same time

Does the “Send” symbol appear

on the display?

Release the button / only press

one button

Batteries in remote control are flat

Have new batteries been inserted?

Is the display incomplete?

Insert new batteries

The unit is running but
only provides reduced
cooling or heating
performance

Filter is unclean / air inlet / outlet

blocked by foreign items

Have the filters been cleaned?

Clean the filters

Doors and windows open. Heating/

cooling output increases

Have modifications been made to

the building?

Close windows and doors / install

additional units

Neither cooling nor heating mode has

been set

Is the cooling/heating symbol

shown on the display?

Correct the settings for the unit

Fins on outdoor component blocked

by foreign items

Is the fan on the outdoor

component running ? Are the fins

unobstructed?

Check the fan or winter controller,

reduce the air resistance

Leaking refrigerant circuit

Are there signs of frost on the fins

of the indoor unit?

Repair by specialist

Condensation is leaking
out of the unit

Drainage pipe on collection container

clogged / damaged

Can the condensation drain off

without any obstruction?

Clean the drainage pipe and

collection container

Faulty external condensation pump

or float

Is the condensation tray full and

the pump running?

Call out a specialist to replace the

pump

Condensation has not drained away

and has collected in the condensation

pipe

Is there a steady fall on the

condensation pipe? Check there is

no blockage in the pipe.

The condensation pipe must have a

fall. If necessary, clean the pipe

Condensation does not drain off

Are the condensation pipes

unblocked and is there a steady

fall? Are the condensation pump

and float switch functioning

correctly?

The condensation pipe must have a

fall. If necessary, clean the pipe.

A faulty condensation pump and

float switch should be replaced.

Malfunction