Remko mkt, Care and maintenance – REMKO MKT 290 User Manual
Page 10
4 Filter change
Permanent shut-down
The entire system should only be
dismantled by a specialist firm
familiar with all environmental
aspects involved.
REMKO GmbH & Co. KG or your
sales partner will be be pleased to
provide details of refrigerant spe-
cialists in your area.
Cleaning the filter
The unit is equipped with two air
intake filters. These can be remo-
ved from the back of the unit. The
filters must be cleaned at regular
intervals. Clean the air filters after
no more than 100 hours of ope-
ration. If the air is heavily conta-
minated, reduce this time period
accordingly.
1. Switch the unit off with the
On/Off button on the control
panel.
2. Remove the filter from the unit.
(Fig. 4)
.
3. Clean the dust that has accu-
mulated from the filter.
You can use a vacuum cleaner.
(Fig. 5)
.
4. If the dust filter is very dirty,
wash it with a lukewarm soap
solution (Fig. 6).
5. Let the filter air dry.
6. Replace the filter in the unit.
(Fig. 4)
.
7. Make sure that the filter is dry
and undamaged.
Never operate the unit without
the air filter.
5 Cleaning with a vacuum cleaner
6 Cleaning with lukewarm water
CAUTION
!
Care and maintenance
Regular care and observation
of some basic points will ensure
trouble-free operation and a long
service life of the unit.
Prior to performing any work,
ensure the equipment is dis-
connected from the voltage
supply and secured to prevent
accidental switch-on!
!
CAUTION
■
Clean the equipment using a
damp cloth.
Do not use a jet of water.
■
Do not use any caustic, abra-
sive or solvent-based cleaning
products.
■
Only use suitable cleaning
agents, even in the event of
severe soiling.
■
Make sure that no moisture
gets into the device. Clean
regularly and thoroughly, the
exhaust air inlet and outlet
openings.There is usually col-
lected first on dirt.
■
It is recommended that you take
out a maintenance contract with
an appropriate specialist firm.
REMKO MKT
10