Control panel – REMKO MKT 260 User Manual
Page 6
6
1 Button "Power"
The unit is switched on or off with this button.
2 Button "Mode"
This button is used to switch the unit to the desired
operating mode. There are three operating modes
available. The signal lights of display 11 indicate the
selected operating mode.
The order is:
Cooling mode: "Cool" signal light
In this operating mode, the unit cools the room to
the set value. The temperature can be set in a
range between 16 and 32 °C. The fan speed can
be freely selected.
Dehumidification mode: "Dehumidifier" signal light
In this operating mode, the unit dehumidifies the
room. The temperature can be set in a range be-
tween 16 and 32 °C. The "Med" fan speed is pre-
set and cannot be changed.
Ventilation mode: "Fan" signal light
In this operating mode, the unit
is used to circu-
late air with no cooling effect. The temperature
cannot be set. The fan speed can be freely se-
lected.
3 Button "Fan Speed"
This button can be used to select a fan speed in the
cooling and ventilating operating modes. Each time
the button is pressed, the speed of the fan changes.
The signal lights of display 10 indicate the selected
speed.
The order is:
Highest fan speed:
"High" signal light
Medium fan speed:
"Med" signal light
Lowest fan speed:
"Low" signal light
4 Button "Timer"
This button can be used to automatically activate the
unit to switch off or on. The signal light 9 indicates
whether the timer is activated.
Control panel
4
3
2
1
7
11
10
6
12
5
8
9
5 Buttons Up/Down "Timer/Temp Adjust"
These buttons can be used to select the desired tar-
get temperature in the cooling and dehumidifying op-
erating modes. If one of the up/down buttons 5 is
pressed, the signal light 7 disappears and the signal
light 8 lights up.
The display now shows the target temperature in-
stead of the room temperature. The target tempera-
ture can be set in a range between 16 and 32 °C in
1°C increments by pressing the buttons 5.
Left button
= Higher target temperature.
Right button = Lower target temperature.
In addition, the up/down buttons 5 can be used to
change the timer period for switching on and off in
all operating modes.
Left button
= Longer time period.
Right button = Shorter time period.
6 Display
The room temperature measured by the internal
sensor of the unit is shown on the display.
If one of the up/down buttons 5 is pressed, the dis-
play switches to show the set target temperature.
If the timer button 4 is pressed, the display switches
to show the remaining number of hours until the unit
will be switched on or off.
If after 15 seconds, no buttons are pressed, the
room temperature appears on the display again.
7 Signal light "Room Temp"
This light indicates that the measured room tempera-
ture is shown on display 6.
8 Signal light "Set Temp"
This light indicates that the currently set target tem-
perature is shown on display 6.
9 Signal light "On/Off"
This light indicates whether a timer has been acti-
vated. It blinks if is possible to make an entry using
the up/down buttons 5.