Spare part list, Technical data – REMKO MKT 260 User Manual
Page 13
13
No. Description
Ref. No.
1 Unit base
1106300
2 Transport roller
1106301
3 Motor with rotating wheel with blades 1106302
4 Capacitor 2,5 µF
1106306
5 Float cpl.
1106304
6 Cover (tank)
1106303
7 Microswitch (tank)
1106305
8 Compressor cpl.
1106307
8a Capacitor 25 µF (compressor)
1106308
9 Condenser
1106309
10 Fan housing, right (exhaust)
1106310
11 Fan wheel (exhaust)
1106311
12 Fan housing, left (exhaust)
1106312
13 Fan motor (exhaust)
1106313
14 Buffer wall
1106314
15 Exhaust adapter
1106315
16 Capacitor 2 µF
1106316
17 Evaporator
1106317
18 Fan housing (circulation)
1106318
Spare Part List
No. Description
Ref. No.
20 Fan motor (circulation)
1106320
21 Cover, top
1106321
22 Circuit board
1106322
23 Power supply with plug
1106323
24 Front wall
1106324
25 Back wall
1106325
26 Air directing flap
1106326
27 Display
1106327
28 Control board
1106328
29
Labelling
(control panel)
1106329
30 Reception board
1106330
31 Recessed grip
1106331
32 Air filter
1106332
33 Remote control
1106333
34 Exhaust hose cpl.
1106334
35 Exhaust hose
1106335
36 Connection adapter
1106336
37 Window nozzle
1106337
19 Fan wheel (circulation)
1106319
When ordering spare parts please indicate ref. no. and machine no. (see type plate)
.
Technical Data
Type
MKT 260
Nominal refrigerating capacity
2)
kW
2,60
Circulating air volume max.
m³/h
420
Fan speeds
3
Exhaust air volume
m³/h
450
Refrigerant
R 407C
Refrigerant amount
g
700
Operating range
°C
16 bis 35
Dehumidification performance max.
l/h
1,6
Sound pressure level
1)
Level 1 / 2 / 3
dB(A)
47 / 50 / 52
Electrical connection
V / Ph / Hz
230 / 1~ / 50
Nominal power consumption
2)
kW
0,95
Nominal current
2)
A
4,50
Energy efficiency class
B
Exhaust hose, lenght / Ø
mm
1250 / 125
Min. distance from the middle of wall lead-through to floor
mm
650
Dimensions
height / width / depth
mm
855 / 510 / 400
Weight
kg
36
Ref. No.
1612260
Power consumption
3)
kW
1,12
Current
3)
A
5,45
Energy efficiency ratio
2,41
Refrigerating capacity
3)
kW
2,70
1) Noise measurement as per DIN 45635 - 01 - KL3
2) Room temperature of db 30 °C / wb 25 °C
3) Room temperature of db 35 °C / wb 24 °C
We reserve the right to make changes to dimensions and design in the interest of technical progress.