Description of device, Operation – REMKO MKT 260 User Manual
Page 5
5
The unit’s primary function is to air-condition rooms.
It also filters and dehumidifies the air, thus creating a
comfortable climate in the room.
In “Fan” mode, the unit
can also be used to circulate air
with no cooling effect. It also has a “Dehumidification”
mode which extracts moisture from the air in the room.
The unit operates fully-automatically and offers a range
of other options thanks to its microprocessor control.
For example, it can be automatically switched off and
on at a preset time via the timer function.
The unit is comfortably operated via the control panel
on the indoor unit or via the infrared remote control that
comes with it.
Description of Device
The MKT 260 portable room air conditioner comes with
an infrared remote control and an air outlet hose with a
flat nozzle.
Operation
Prior to putting the unit into operation, ensure that all
safety instructions have been observed.
Please note that the unit operates most efficiently and
most comfortably when put into operation before the
hottest part of the day, e.g. the morning.
The selected target temperature should be 4 to 7 °C be-
low the outside temperature. It should never be lower
because the room temperature would feel too cold
when coming from a non-air-conditioned room and peo-
ple may catch cold.
The selected target temperature does not affect the
performance of the unit! This means that when tem-
peratures in the room are high, it is not practical to ad-
just the unit to the lowest possible target temperature.
The unit has been designed for automatic, universal,
smooth air dehumidification. Its compact dimensions
make it easy to transport and set up in all rooms.
The unit meet the basic safety and health requirements
found in the relevant EU regulations. It is safe and easy
to operate.
Functional principal
The portable air conditioner cools the air in the room by
extracting heat from it. The heat absorbed is expelled to
the outside via the exhaust hose and the cooled air is
resupplied to the room where the unit is in operation via
a fan.
Condensation that accumulates drips from the evapora-
tor onto the hot condenser where it condenses and is
then transported via the air outlet hose to the outside.
Excess condensation drips from the condenser into a
collection tray and is resupplied to the condenser by
means of a rotating wheel with blades, where it evapo-
rates and is then expelled with the outgoing air current.
Control panel
Air flap
IR receiver
Transport
wheels
Recessed grip
Condensation-
drain with plug
Air intake with
air filter
Air outlet hose
Cable holder
Connection line
with plug
Air intake
exhaust
Air outlet
exhaust
The environmentally-friendly refrigerant, R 407C, trans-
ports the absorbed heat within the closed-loop refriger-
ant cycle.
Cool circulating
air in the room
Warm air ex-
pelled to the
outside
Evaporator
Condenser
Refrigerant
cycle
Fan for
circulation
Fan for out-
going air
Compressor
Expelled air
intake
Circulation
intake