beautypg.com

Quintum Technologies CDR User Manual

Page 9

background image

Quintum Tenor CMS CDR

Page 7

H

208.226.140.57

Local IP Address

The IP address of the Local-side Tenor CMS. The
entry will be in the following format:
xxx.xxx.xxx.xxx.

I

192.168.10.64

Remote IP Address

The IP address of the Remote-side Tenor (or other
Gateway). This will be generated only if the call is
VoIP; if the call is circuit based, this field will be
blank. The entry will be in the following format:
xxx.xxx.xxx.xxx.

J

4

Origination Trunk Id

Identifies the origination trunk ID of the line that
initiated the call. This field will be blank if no trunk
ID is configured. The trunk ID is often configured
with an account code.

K

1

Call Type

The type of call. Valid entry: 1 = voice, 2 = fax,
3 = modem, 4 = data.

L

1

Call Number Type

The called numbering plan used for the call per
Q.931. Possible common entries are as follows:
1 = Public/E.164, 9 = Private.

M

1

Incoming Digital
Interface

If the call is incoming, this field identifies which line
the call came in on. Valid entry: 1 to 8. This field
will be empty if the call is an incoming VoIP call.

N

1

Incoming Channel

If the call is incoming, this field identifies which
channel the call came in on. Valid entry: 1-31. This
field is empty if the call is an incoming VoIP call.

O

1

Outgoing Digital
Interface

If the call is outgoing, this field identifies which line
the call is going out on. Valid entry: 1 to 8. This
field will be empty if the call is an outgoing VoIP
call.

P

1

Outgoing Channel

If the call is outgoing, this field identifies which
channel the call went out on. Valid entry: 1-31.
This field will be empty if the call is an outgoing
VoIP call.

Q

null

Auto Switch Time

This is the date and time the AutoSwitch occurred
(when the call is switched from VoIP to circuit).
The entry will be in the following format:
yyyymmddhhmmss where yyyy (4 digits for year),
mm (2 digits for month), dd (2 digits for day), hh (2
digits for hour), mm (2 digits for minutes), ss (2
digits for seconds). If an AutoSwitch did not occur,
this field will be blank.

Table 3: Standard Format Fields - Settings 0 & 100

ID

Sample Setting

Field Name

Definition