Cdr field definitions: extended-cms format fields, Settings 3 & 103 – Quintum Technologies CDR User Manual
Page 11

Quintum Tenor CMS CDR
Page 9
CDR Field Definitions: Extended-CMS Format Fields
Settings 3 & 103
Sample CDR Record (the actual field output would be separated by commas)
1, 17325551212, 15, 20020107062812, 20020107062815, 20020107063819, 16, 209.222.143.57, 192.168.10.64, 4, 1, 1,
| | | | | | | | | | | |
A B C D E F G H I J K L
5, 1, 1, 1, 3, 1, 4, 1, , , 0, 0, 14155551000, 12345678901234, 987654321, 123456789,
| | | | | | | | | | | | | | | |
M N O P Q R S TUV W X Y X AA AB
Record Field Definitions – Standard Formats 3 and 103
1 (CDR Seq#), 17325551212 (Called Number), 15 (Duration), 20020107062812
(Call Initiation Time), 20020107062815 (Call Connected Time), 20020107063819
(Call Disconnected Time), 16 (Cause Code), 209.222.143.57 (Local IP Address),
192.168.10.64 (Remote IP Address), 4 (Origination Trunk ID), 1 (Call Type), 1
(Call Number Type), 5 (Incoming Slot), 1 (Incoming Device), 1 (Incoming Line),1
(Incoming Channel), 1 (Outgoing Line), 1 (Outgoing Channel), blank (AutoSwitch
Time), blank (AutoSwitch Duration), 0 (Bad IP Quality Events), 0 (AutoSwitch
Flag), 1415551000 (Calling Party Number), 12345678901234 (PIN Code),
987654321 (Local Call ID #), 123456789 (Remote Call ID#)
Table 5: Extended-CMS Format - Settings 3 & 103
ID
Sample Setting
Field Name
Definition
A
1
CDR Sequence
Number
Sequence number. This is a unique number
assigned to identify an individual call (e.g, 1, 2, 3,
…). The sequence number starts from 1 and
wraps around at 4,294,967,295. When a Tenor
resets, the sequence number starts from 1 again.
If the system has a problem and loses
connectivity, the CDR server can send the Tenor
the last Call ID that it received. Tenor will reply with
all records that contain a Call ID, which is greater
than the one last received.
B
17325551212
Called number
The number called. This will be in international
format except for a pass-through call going from
Line-Side to the Trunk-Side or from Trunk-Side to
the Line-Side.
C
15
Duration (seconds)
This value is in seconds. The value will be 0 if
never connected.