beautypg.com

Installation, Caution – Profax PRO II x User Manual

Page 9

background image

1. Remove hinged cover.
2. Locate TS2 terminal strip.
3. Remove the two jumper links from TS2.
4. Install the 115/24 VAC transformer (St./No. 9045) onto it's mounting holes using the supplied four 8/32 screws, washers,

lockwashers and nuts.

5. Cut the transformer wires back so as to neatly reach their respective TS2 terminal listed in step 6.
6. Install the supplied spade wire terminals to the transformer wires.
7. Connect the transformer wires to terminal strip TS2 as follows:

White

to

Terminal 1

Yellow

to

Terminal 2

Yellow

to Terminal

3

Black

to

Terminal 4

8. Install the hinged cover making sure not to trap and or pinch any wiring.

®

®

®

®

7

6

Installation

Installation

1. Wire Speed Control

2. Power Switch and Power "ON" Light

3. Euro-Quick Adapter

CONTROL PANEL

THREADING WELDING WIRE AND ADJUSTING TENSION

OPTIONAL 115/24 VAC TRANSFORMER INSTALLATION

TS1 CONTACTOR TERMINAL STRIP OPERATION

SPOOL BRAKE ADJUSTMENT

1. Release pressure arm(s) by sliding the tension

5. Holding the mig gun out straight, feed the welding wire

adjustment lever(s)down.

through the mig gun by using the gun trigger.

2. Route the welding wire through the inlet guide

6. Reinstall the contact tip.

across the drive roll(s) and into the outlet guide.

7. To adjust drive roll pressure - hold the mig gun no less

Slide at least six inches of wire into the outlet guide.

than four inches up from a wood surface. Press the

3. Close pressure arm(s) and secure by sliding the

gun trigger to feed wire and tighten the wire tension adjust

tension adjustment lever(s) up until locked in place.

ment knob to the point where the wire does not slip.

4. Remove the mig gun contact tip.

8. Cut off wire and close cover.

NOTE:

Too much wire tension will damage motor, cause erratic feeding and excessively wear drive rolls

1. Tension should be adjusted with wire spool on feeder.
2. Remove wire spool securing nut.
3. Turn the tension adjustment nut to the right to increase braking tension.
4. Adjust until a slight force is felt as you turn the spool by hand.
5. Install wire spool securing nut.

NOTE:

Too much brake tension will cause erratic feeding.

WOOD

TIGHTEN

SPOOL

SECURING NUT

TIGHTEN

TENSION

NUT

SPINDLE

ASSY.

3

1

2

TS2 SET FOR

115 VAC OPERATION

TS2 SET FOR

24 VAC OPERATION

JUMPER

LINKS

YELLOW
YELLOW

WHITE

BLACK

CONTACT CLOSURE OPERATION

This setting is for welding power sources that require a normally open set of

contacts to operate the contactor. When the normally open set of contacts on K1
relay close it completes the circuit and energizes the contactor. Pins F and E on RC1
will give contact closure operation by the wire feeder when the TS1 jumper is from
terminal 1 to 2.

VOLTAGE FEEDBACK CONTACTOR OPERATION

This setting is for power sources that require voltage feedback to operate the

contactor. When K1 relay closes voltage will be sent back to the welding power
source to energize the contactor. This setting is normally used with the 115/24 VAC
transformer option (St./No. 9045) to send 115 VAC back to the welding power
source to operate the contactor circuit. Pins F and B on RC1 will give voltage
feedback operation by the wire feeder when the TS1 jumper is from terminal 2 to 3.

1

2

3

CONTACT

CLOSURE

VOLTAGE

FEEDBACK

1

CONTACT

CLOSURE

2

3

VOLTAGE

FEEDBACK

CAUTION!

Jumper links on TS2 must be removed when
installing the 9045 115V transformer option.
Failure to remove links will cause the pc board
to fail and void warranty.