OWON HDS1021M Handheld DSO & DMM

8-Advanced Function of Oscilloscope

Term interpretation

Vpp: Peak-to-Peak Voltage.

Vmax: The maximum amplitude. The most positive peak voltage measured over the entire
waveform.

Vmin: The minimum amplitude. The most negative peak voltage measured over the entire
waveform.

Vamp: Voltage between Vtop and Vbase of a waveform

Vtop: Voltage of the waveform’s flat top, useful for square/pulse waveforms.

Vbase: Voltage of the waveform’s flat base, useful for square/pulse waveforms.

Overshoot: Defined as (Vmax-Vtop)/Vamp, useful for square and pulse waveforms.

Preshoot: Defined as (Vmin-Vbase)/Vamp, useful for square and pulse waveforms.

Average: The arithmetic mean over the entire waveform.

Vrms: The true Root Mean Square voltage over the entire waveform.

Rise Time: Time that the leading edge of the first pulse in the waveform takes to rise from 10%
to 90% of its amplitude.

Fall Time: Time that the falling edge of the first pulse in the waveform takes to fall from 90% to
10% of its amplitude.

+Width: The width of the first positive pulse in 50% amplitude points.

-Width: The width of the first negative pulse in the 50% amplitude points.

+Duty: +Duty Cycle, defined as +Width/Period

-Duty: -Duty Cycle, defined as -Width/Period.

8.10 Setting the Cursor Measurements

This oscilloscope allows you to make manual cursor measurements on time and voltage..

The cursor measurement menus are listed and described in the following table.

Function menus

Settings

Description

Type

OFF

Voltage

Time

Close the cursor measurement.
Display the voltage measurement cursor and menu.
Display the time measurement cursor and menu.

Delta

Display the difference of measured value between the
two cursors.

Cur1

Display the relating measured value of Cursor 1.

Cur2

Display the relating measured value of Cursor 2.

To make a voltage measurement, doing the following:

45