beautypg.com

Osburn OB04002 User Manual

Page 72

background image

Stratford

Fireplace Installation and Operation Manual

72 _____________________________________________________________________

3.

Secure the ducting (A) to the 90° elbows (E) with self-tapping screws (3 per elbow). Insert the
hot air outlets (F) in the elbow (E). Set hot air outlets frames behind the non-combustible
materiel and secure to the wall with screws. Secure hot air outlets (F) to the elbows (E) with 3
self-tapping screws each. Secure the hot air outlets grilles to the frames with screws.

4.

Maintain at least a 2" (50 mm) clearance between the ducts and the firestop; the required hole
size for the hot air grilles (outlet) is 8¼" × 8¼" (210 mm × 210 mm).

5.

The maximum number of elbows in a run of duct is two.

6.

Maintain at least 10" (254 mm) clearance from the outlet grille framing to a combustible
ceiling, side wall or mantel.

This manual is related to the following products: