Osburn OB04002 User Manual
Page 61
Stratford
Fireplace Installation and Operation Manual
_____________________________________________________________________ 61
TABLE 2 - LISTED CHIMNEYS FOR YOUR STRATFORD
WARNING: IN EVERY CASE, THE CHIMNEY MUST START WITH A 6'' DIAMETER ANCHOR PLATE
SECURED TO THE FIREPLACE.
*This fireplace may be installed with a 7-inch chimney from “Security Chimney” as indicated it the
table above.
Refer to the following table to determine the parts you will need depending on the type of
fireplace used: (R: Required, NR: Not Required).
CHIMNEY
MANUFACTURER
BRAND
TYPE
INNER DIAMETER
Selkirk
Ultra-Temp (UT)
1” Solid Pack
6" (15 cm)
Selkirk
Super Pro (SPR)
1” Solid Pack
6" (15 cm)
Selkirk
Super Vent (JSC)
1” Solid Pack
6" (15 cm)
Selkirk
Hart & Cooley (TLC)
1” Solid Pack
6" (15 cm)
Selkirk
Sure-Temp (ST)
1” Solid Pack
6" (15 cm)
Selkirk
CF Sentinel (CF)
2” Solid Pack
6" (15 cm)
Selkirk
Super Pro 2100 (ALT)
2” Solid Pack
6" (15 cm)
Selkirk
Super Vent 2100 (JM)
2” Solid Pack
6" (15 cm)
Selkirk
UltimateOne
1” Solid Pack
6" (15 cm)
Security Chimney
ASHT+
1” Solid Pack
6" or 7" (15 or 18 cm)*
Security Chimney
S-2100 +
2” Solid Pack
6" or 7" (15 or 18 cm)*
Simpson Dura Vent
Dura Tech
1” Solid Pack
6" (15 cm)
Simpson Dura Vent
Dura Plus HTC
2” Solid Pack
6" (15 cm)
Simpson Dura Vent
Dura Plus
AC Triple Wall
6" (15 cm)
ICC
Excel 2100
1” Solid Pack
6" (15 cm)
Metal Fab
Temp Guard
1” Solid Pack
6" (15 cm)
American Metal
HSS
AC Triple Wall
6" (15 cm)
American Metal
HS
AC Triple Wall
6" (15 cm)
Olympia Chimney
Ventis
1” Solid Pack
6" (15 cm)
FMI (U.S.A. only)
AC
AC Triple Wall
6" (15 cm)