beautypg.com

7clearances to combustible material – Osburn OB04002 User Manual

Page 50

background image

Stratford

Fireplace Installation and Operation Manual

50 _____________________________________________________________________

7

CLEARANCES TO COMBUSTIBLE MATERIAL

The clearances shown in this section have been determined by test according to procedures set
out in safety standards ULC S610 (Canada) and UL127 (U.S.A.). When the fireplace is installed so
that its surfaces are at or beyond the minimum clearances specified, combustible surfaces will not
overheat under normal and even abnormal operating conditions.

No part of the fireplace may be located closer to combustibles than the minimum clearances
given below.

The following clearances meet the minimum requirements for a safe installation.

Side wall: 17" (43 cm) measured from the inside door frame.

Side mantle: 3" minimum

Wall in front of fireplace: 48"

Ceiling: 80 in. (2.03 m) measured from the base of the fireplace.

Fireplace enclosure:

Back wall: 0"

Sides: 0"

Floor (under the fireplace): 0"

Chimney: 2" (50 mm)

Combustible shelf:

58" (147 cm) measured from the base of the fireplace for a shelf with a depth of 6" (15 cm)
or less.

64" (163 cm) measured from the base of the fireplace for a shelf with a depth of more than
12" (30 cm).

7.1

LOCATING THE CERTIFICATION LABEL

Since the information given on the certification label attached to the appliance always overrides
the information published in any other media (owner’s manual, catalogues, flyers, magazines
and/or web sites), it is important to refer to it in order to have a safe and compliant installation. In
addition, you will find information about your fireplace (model, serial number, etc.). You can find
the certification label beneath the fireplace, behind the bottom louver.

This manual is related to the following products: