TABLE 3 – LIST OF MANDATORY COMPONENTS
CHIMNEY
MANUFACTURER
MANDATORY COMPONENTS
TYPE/BRAND
Selkirk
•
Ventilated roof flashing.
•
Must have rafter protectors at the
roof level if the chimney is enclosed
at the attic level.
Ultra-Temp (UT), Super Pro
(SPR), Super vent (JSC), Hart
& Cooley (TLC), Sure-Temp
(ST)
Security Chimney
•
Rafter protector at the roof level if
chimney is enclosed at the attic
level.
•
Requires insulated attic radiation
shield unless chimney is enclosed at
the attic level.
•
Requires the use of a 6AW7 (Solid
pack 1") adapter for a ASHT+ of 7".
•
Requires the use of a 6AW7 and a
7UCA adapter for the S-2100 of 7".
1" Solid Pack: ASHT+,
2" Solid Pack : S-2100
Simpson Dura-Vent
•
Ventilated roof flashing.
•
Rafter protector at the roof level is
chimney is enclosed at the attic
level.
1" Solid Pack : Dura Tech
ICC
•
Ventilated roof flashing.
•
Rafter protector at the roof level if
chimney is enclosed at the attic
level.
Excel 2100
American Metal
•
Chimney cannot be enclosed at the
attic level.
AC
Triple
wall
HS,
AC Triple wall HSS
*You can get a kit of four (4) rafter protector (AC03510) from
your dealer. Each rafter is made of 22GA galvanized steel
(10.44”W x 5.126”H).
10.44”
5.126”
1.530”
.512”