S
PECIFICATION
Clock type
Class 1 Master Clock with dual VCXO, temperature compensated.
Clock Frequencies
44.1kHz or 48kHz.
Clock Accuracy
Better than +/- 1ppm when shipped (guaranteed for 12 months from
shipping), typically +/-0.1ppm when shipped and stabilised.
Word Clock Outputs
8 independently buffered outputs on 75
Ω BNC connectors, all carry the same
clock frequency.
Reference Input
External Reference Input on 1x 75
Ω BNC connector. Accepts word clock
(with the
Coupling
menu page set to
TTL
) or AC coupled signals (with the
Coupling
menu page set to
Bipolar
) at 32kHz, 44.1kHz, 48kHz, 88.2kHz,
96kHz, 1MHz, 5MHz or 10MHz. Lock range is +/-300ppm.
Start-up time
Typically 1 minute to rated accuracy.
Size and weight
460mm (18.0”) long x 405mm (15.9”) deep x 73mm (2.9”) high. Allow extra
depth for cable connectors.
9.8kg (21.6lbs).
Power requirements
Internally set to either 100, 115/120, 220 or 230/240V AC, 49 – 62Hz.
Power consumption: 8W typical, 12W maximum.