beautypg.com

ONICON F-3100 Series User Manual

Page 28

background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-3100 Flow Meter Manual 06/14 - 0670-7

Page

28

0516

Remove retaining screw to
expose connector.
(Shown with High Voltage)

Power connections
are under this cover.

Pulse Out 1
Pin 16 - Pos (+)
Pin 17 - Neg (-)

Pulse Out 2
Pin 18 - Pos (+)
Pin 19 - Neg (-)

4-20 mA Output
Pin 9 - Pos (+)
Pin 10 - Neg (-)

5-15-08

SIGNAL CONNECTIONS

POWER CONNECTIONS

Step 1:

Loosen screws to lift cover.

Step 2:

Lift cover to expose electrical connections.

Step 3:

Make SIGNAL connections as shown

Pull straight out on connectors to remove them.

Step 4:

Open cover to expose POWER Connections.

Opto-coupled open collector pulse outputs
Maximum voltage: 40VDC
Maximum current: 100mA
Maximum saturation voltage collector/emitter @ 100mA: 3 VDC

Pulse Output 1 / Pulse Output 2