beautypg.com

ONICON F-1100 Series User Manual

Page 45

background image

11451 Belcher Road South, Largo FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
Turbine Flow Meter Manual 05/14 - 0721-3 / 13518

Page B-6

11451 South Belcher Road, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-4599

www.onicon.com • [email protected]

0543-3 / 15954

04-14

For Use With Kits: INSTL10, INSTL11, INSTL12, INSTL13,

INSTL14, INSTL15, INSTL16, INSTL17

Pipe saddle types vary by application.

Important Note

ONICON provides pipe saddles to facilitate the installation of our flow meters. Separate

installation instructions accompany the saddle. Please follow these instructions when installing

the saddle. Pay particular attention to bolt torque specifications and temperature/pressure limits.

Installation Hardware Instructions

Standard Installation Kit for Applications Requiring Pipe Saddles

For F-1100, F-1200 & FB-1200 Series Insertion Turbine Flow Meters

This kit must be installed prior to filling the system, or into a section of pipe that is isolated from

pressure and flow. Once installed, this kit allows for insertion and removal of the flow meter without

a system shutdown.
Directions:

1. Identify an appropriate location for the flow meter

(see pages 2-4).

2. Clamp the saddle onto the pipe; refer to

manufacturer’s instructions.

3. Drill a 1” (minimum) access hole in the pipe,

centered in the outlet.

4. Install the reducer, close nipple and ball valve as

shown below. Use a paste type thread sealant.

DO NOT use Teflon

®

tape.

5. Flush and fill the system prior to installing the

meter.

NOTE: Before installing the flow meter, read the entire installation manual.

Important Note

ONICON insertion flow meters

are precision measuring devices

that must be installed according to

the instructions contained in this

document in order to maintain their

accuracy and reliability. Failure to

follow these instructions will result

in erratic operation and reduced

accuracy.

*

*

Bushing may not be

required in all cases.

(see Sections 3.1 and 3.2).

This manual is related to the following products: