Specifications
1.5.1
Electrical Specifications
Input
Power:
16-33
Vdc.
Current:
0.25 A/LED Control 250 Series
0.35
A/LED
Control
350
Series
0.45
A/LED
Control
450
Series
0.15
A/LCD
Control
400
Series
+0.075 A/Interface Card Installed (for all types)
+0.250
A/28
Vdc
for
panel
lighting
Values above are maximum, display set to full intensity.
Panel
Indicators:
Two-colour LED indicates: TX - Green
RX (SQ) - Orange
One LED per radio, except when the interface
supports separate guard controls (‘U’, ‘V’, etc.), in
which case a second LED is provided for the guard
receiver.
Channel
Storage:
CH-series
(Tac/Com I)
32/56 Channels per radio
TH series (Tac/Com II)
128 Channels per radio
Data
Interface:
Programming
via
standard RS-232 from a PC (NAT
software), or front panel for all functions.
Scanning:
NT -series transceivers: 90 channels/second/radio.
NTX -series transceivers: 10-20 channels/second/radio.
Modes are LIST, PRIORITY, LIST + PRIORITY.
Priority monitoring is 3 times/second for 10-15 ms sample.
Radio will re-channel to the priority channel if traffic is
detected, and returns to the monitor channel after a 2
second latency.
All CTCSS tones or DPL codes are inactive during
scanning (due to lock delay).
Other
scanning
parameters depend on the radio type.
Jan 4, 2006