G016.J

®

1. No power to heater
2. Thermostat setting to low

3. Bad electrical connection between motor

and ignition control assembly or ignition
control assembly and power cord

4. Blown fuse on ignition control assembly
5. Binding pump rotor

6. Defective ignition control assembly
7. Defective motor

1. No fuel in tank
2. Pump pressure incorrect
3. Dirty fuel filter
4. Obstruction in nozzle assembly
5. Water in fuel tank

6. Defective fuel valve
7. Bad electrical connection between

ignitor and ignition control assembly

8. Defective ignitor
9. Defective ignition control assembly

1. Pump pressure incorrect
2. Dirty air intake, air output, and/or lint

filter

3. Dirty fuel filter
4. Obstruction in nozzle assembly
5. Photocell assembly not properly

installed (not seeing the flame)

6. Dirty photocell lens
7. Bad electrical connection between

photocell and ignition control assembly

8. Defective photocell
9. Defective ignition control assembly

Troubleshooting Chart

Possible Cause(s)

Corrective Action

Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.

Symptom

High Voltage!

Motor does not start five seconds after
heater is plugged in

Motor starts and runs but heater does not
ignite

Heater ignites but ignition control
assembly shuts heater off after a short
period of time

1. Check circuit breaker in electrical panel
2. Turn thermostat knob clockwise to a

higher setting

3. Check all electrical connections. See

Wiring Diagram, page 14

4. See Ignition Control Assembly, page 9
5. If fan does not turn freely, see Pump

Rotor, page 8

6. Replace ignition control assembly
7. Replace motor

1. Fill tank with kerosene
2. See Pump Pressure Adjustment, page 6
3. See Fuel Filter, page 7
4. See Nozzle Assembly, page 8
5. Drain and flush fuel tank with clean

kerosene. See Storing, Transporting, or
Shipping,
page 9

6. See Fuel Valve, page 7
7. Check electrical connections. See

Wiring Diagram, page 14

8. Replace ignitor, see page 7
9. Replace ignition control assembly

1. See Pump Pressure Adjustment, page 6
2. See Air Output, Air Intake, and Lint

Filters, page 6

3. See Fuel Filter, page 7
4. See Nozzle Assembly, page 8
5. Make sure photocell boot is properly

seated in bracket

6. Clean photocell lens
7. Check electrical connections. See

Wiring Diagram, page 14

8. Replace photocell
9. Replace ignition control assembly

High Voltage!

High Voltage!