beautypg.com

Norsat 25W ATOM User Manual

Page 20

background image

ATOM 25W/40W/50W

Revision 1.1

908239

20

908239_r1.1 - Operator Manual ATOM KU

25-40-50W.doc

Table 2-4: J3 Connector Pin Out

Pin

Name

A

Ground or V-

B V+
C V+
D

Ground or V-

Positive voltage is applied to pins B and C (connected internally). Negative voltage is applied to pins A
and D (connected internally).

Pins A and D are connected internally to case ground.

Section 2.6
J4

RF

OUTPUT

The output is a standard WR75 or WR62 square waveguide. Specify which flange is to be installed at
time of order. Both types of flanges have a groove for an O-ring seal, which is highly recommended to
keep moisture out of the unit.

Also, for outdoor installations, after bolting the waveguide-to-waveguide connection, it is recommended to
add RTV silicone compound as a sealant around the entire perimeter of the joint where the flanges meet.
This will provide extra protection against water ingress at the flange-to-flange interface.

The unit is supplied with two screw lengths (four 6-32x3/8" and four 6-32x7/16"); it is the users
responsibility to ensure that the appropriate length of screw is used. There should be at least 4 threads of
engagement (0.125") with the holes in the waveguide flange.

Section 2.7
G

ROUND

C

ONNECTION

The unit is supplied with a 10-32 screw and internal tooth lock washers for grounding purposes. It is
highly recommended that the unit is grounded according to national and local electrical codes before use.

This manual is related to the following products: