beautypg.com

Norsat 25W ATOM User Manual

Page 18

background image

ATOM 25W/40W/50W

Revision 1.1

908239

18

908239_r1.1 - Operator Manual ATOM KU

25-40-50W.doc

Each command response will have the following format:

where msg is as described above and in the commands summary and example tables below. Note that a
response is enveloped by leading and trailing characters.

Table 2-3: Commands Summary

Command

Param-Value

Pairs

Response Format

(enveloping characters not shown)

getident

None

ok pn swver sn

where:

= unit part number label

= software version label

= unit serial number label

getstatus

None

ok fault fwdpwr revpwr temp

where:

= fault flag, either 0 (no fault) or 1 (fault) .

Use the getfaults command to determine the specific fault(s)

= forward power value, in dBm

= currently not used but reserved for reverse power

= internal system temperature in degrees Celsius

getfaults

None

ok mute overTemp pll

where:

= 0 (unit unmuted) or 1 (unit muted)

= 0 (temp ok) or 1 (error - over temp condition exists)

= 0 (pll ok) or 1 (error – pll loss of lock)

resetfaults

None

ok

setmute cmd (0|1)

0 = unmute

1 = mute

ok

M

UTE

L

OGIC

The unit will be muted when any of the following conditions exist:

1. A software mute command is issued through the serial interface.

2. A mute command/signal is issued through the discrete SHUTDOWN line (

Pin D: Shutdown (i.e.

Mute Control)

.

3. A fault condition exists.

This manual is related to the following products: