Sspa, Onitor and, Ontrol – Norsat 25W ATOM User Manual
Page 11: Nterface
ATOM 25W/40W/50W
Revision 1.1
908239
11
908239_r1.1 - Operator Manual ATOM KU
25-40-50W.doc
SSPA
In the SSPA-only configuration, this is the RF input. It is a precision type-N connector, with performance
to 18GHz. No 10 MHz reference is required for SSPA-only operation.
Section 2.3
J2
–
M
ONITOR AND
C
ONTROL
I
NTERFACE
The serial interface is used to interface the unit to a host computer. All on-board sensors are read through
this interface, including forward power monitoring. In default mute configuration (refer to section
Pin D:
Shutdown (i.e. Mute Control)
), use of this connection is optional.
P
IN
O
UTS
The monitor and control interface is a ten pin connector.
CAUTION: EXTREME CARE MUST BE USED WITH THIS CONNECTOR TO AVOID ELECTRO
STATIC DISCHARGE (ESD). Many units have been damaged by improper ESD precautions. Always use
industry-standard practices including wrist straps when coming within six inches of these connectors or
any accessories or cables to be attached to this.
The connector is a cannon type connector with a 12-10 configuration with pins (Amphenol part number
71-533723-10P). This connector is a MIL-C-26482 Series 1 receptacle, Shell size 12, 10 pins. The
connector is a “receptacle” and it has pins (as opposed to sockets), and requires the mating connector to
be a “plug” with ten sockets. An example mating connector would be Amphenol #PT06A-12-10S. A range
of other plug-compatible Amphenol part numbers for the mating connector may be used to add options to
the plug such as right-angle, stress relief clamp, metal color/finish, etc. Please contact the connector
manufacturer for more information and/or see Amphenol catalog 12-070.
The pin outs are given in Table 2-1 and shown in
Figure 2-1
.
Table 2-1: J2 Pin Outs
Connector Pin
Function
Description
A
TX- (RS-485)
Host computer TX- signal (signal into unit)
B
TX+ (RS-485)
Host computer TX+ signal (signal into unit)
C
RX+ (RS-485)
Host computer RX+ signal (signal out of unit)
D
SHUTDOWN
Controls Muting of Amplifier
E
RX (RS-232)
Host computer RX signals (signal out of unit)
F
TX (RS-232)
Host computer TX signals (signal into unit)
G
GND
Case Ground – Do not exceed 100mA
H
GND 2
Case Ground – Do not exceed 100mA
J
RX- (RS-485)
Host computer RX- signal (signal out of unit)
K
Reserved
Leave unconnected / open circuited