Sspa, Onitor and, Ontrol – Norsat 25W ATOM User Manual

Page 11: Nterface

background image

ATOM 25W/40W/50W

Revision 1.1

908239

11

908239_r1.1 - Operator Manual ATOM KU

25-40-50W.doc

SSPA

In the SSPA-only configuration, this is the RF input. It is a precision type-N connector, with performance
to 18GHz. No 10 MHz reference is required for SSPA-only operation.

Section 2.3
J2

M

ONITOR AND

C

ONTROL

I

NTERFACE

The serial interface is used to interface the unit to a host computer. All on-board sensors are read through
this interface, including forward power monitoring. In default mute configuration (refer to section

Pin D:

Shutdown (i.e. Mute Control)

), use of this connection is optional.

P

IN

O

UTS

The monitor and control interface is a ten pin connector.

CAUTION: EXTREME CARE MUST BE USED WITH THIS CONNECTOR TO AVOID ELECTRO
STATIC DISCHARGE (ESD).
Many units have been damaged by improper ESD precautions. Always use
industry-standard practices including wrist straps when coming within six inches of these connectors or
any accessories or cables to be attached to this.

The connector is a cannon type connector with a 12-10 configuration with pins (Amphenol part number
71-533723-10P). This connector is a MIL-C-26482 Series 1 receptacle, Shell size 12, 10 pins. The
connector is a “receptacle” and it has pins (as opposed to sockets), and requires the mating connector to
be a “plug” with ten sockets. An example mating connector would be Amphenol #PT06A-12-10S. A range
of other plug-compatible Amphenol part numbers for the mating connector may be used to add options to
the plug such as right-angle, stress relief clamp, metal color/finish, etc. Please contact the connector
manufacturer for more information and/or see Amphenol catalog 12-070.

The pin outs are given in Table 2-1 and shown in

Figure 2-1

.

Table 2-1: J2 Pin Outs

Connector Pin

Function

Description

A

TX- (RS-485)

Host computer TX- signal (signal into unit)

B

TX+ (RS-485)

Host computer TX+ signal (signal into unit)

C

RX+ (RS-485)

Host computer RX+ signal (signal out of unit)

D

SHUTDOWN

Controls Muting of Amplifier

E

RX (RS-232)

Host computer RX signals (signal out of unit)

F

TX (RS-232)

Host computer TX signals (signal into unit)

G

GND

Case Ground – Do not exceed 100mA

H

GND 2

Case Ground – Do not exceed 100mA

J

RX- (RS-485)

Host computer RX- signal (signal out of unit)

K

Reserved

Leave unconnected / open circuited