3.2.2 Router extension mode on 16x2 routers
Switches 5 -
6 on the configuration switch set the router’s input offset in systems with 2 or
more 16x2 Sublime routers. You may build routers up to 128x2 with audio signal formats,
except for SL-AD1602 that may be extended to 64x2. The chosen input offset defines the
input range each 16x2 router works on.
Configurable panels cannot detect input offset on 16x2 routers. It is therefore
important to remember to re-program the local control panel on 16x2 routers
with input offset >0. See also Chapter 7 for more information.
The modes of the SL-AD1602-110(-CP) routers can be switched according to the following
pattern:
SW 5
SW 6
SW 8
Input offset
OFF
OFF
OFF
0 (Inputs 1-16)
OFF
OFF
ON
1 (Inputs 17-32)
OFF
ON
OFF
2 (Inputs 33-48)
OFF
ON
ON
3 (Inputs 49-64)
ON
OFF
OFF
4 (Inputs 65-80)
ON
OFF
ON
5 (Inputs 81-96)
ON
ON
OFF
6 (Inputs 97-112)
ON
ON
ON
7 (Inputs 113-128)
The modes of the SL-AD1602-75(-CP) routers can be switched according to the following
pattern:
SW 5
SW 6
SW 8
Input offset
OFF
OFF
ON
0 (Inputs 1-16)
OFF
ON
ON
1 (Inputs 17-32)
ON
OFF
ON
2 (Inputs 33-48)
ON
ON
ON
3 (Inputs 49-64)
Default mode for both routers is 0 offset.
3.3 Power alarm
The power alarm can be switched according to the following pattern:
SW 7
Power alarm
OFF
Disables Power Alarm
ON
Enables Power Alarm
Default setting is Power Alarm disabled.
3.4 Power-up mode
Switch 8 on the configuration switch defines the power up mode on NxN square routers.
The Sublime router provides two modes for powering up the system.
The power up options can be switched according to the following pattern:
SW 8
Power Up mode
OFF
Switches all outputs according to the buffered
information in the routers processor system.
ON
Switches all outputs to input 1.
Default setting switches all outputs according to the buffered information in the routers