Repair - disassembly – MovinCool 24HFU Service Manual User Manual
Page 35

MOVINCOOL 24HFU / 24HFU-1 SERVICE
PAGE 35
REPAIR - DISASSEMBLY
3-3-1.
Remove the set bolt using a box
wrench and then remove the
centrifugal fan.
■ Removal of Blower Screw
3-3-2.
Remove two nuts as depicted.
Also remove two screws which fasten the
upper panel. Then remove the blower
housing (condenser).
A - NUT
B - SCREW
■ Removal of Nut
3-3-3.
Remove two nuts and two screws
as depicted.
Then remove the motor bracket together
with the fan motor.
A - NUT
B - SCREW
■ Removal of Nut
3-3-4.
Remove the centrifugal fan by
loosening the set bolt on the shaft.
Remove the blower motor, by loosening
“A” nuts.
■ Removal of Fan