Recommended spart parts list – MK Products Prince XL MM Com ACWC User Manual
Page 15
Prince
®
XL Millermatic Compatible Gun Owner's Manual - Page 8
Idler Roll
005-0686
Recommended Spart Parts List
Part Number
Description
615-0620-15
Conduit 15’
615-0620-25
Conduit 25’
615-0620-35
Conduit 35’
615-0620-50
Conduit 50’
005-0661
Potentiometer Kit
003-0568
Micro Switch
005-0633
Handle Kit
511-0101
Drive Roll
005-0686
Idler Roll Kit
325-0206
Idler Roll Screw
333-0082
Idler Roll Washer
003-0585
Trigger Assy.
431-3117
Door
Micro Switch Assy
(switch with leads)
003-0568
Drive Roll
511-0101
Section E
Troubleshooting
All MK Products push-pull guns operate on the same principle. The 115
VAC or 42VAC slave motor in the feeder runs at a fast, constant speed, but
has very low torque; it is always trying to feed more wire than the gun motor
wants, and when the gun motor gets all it wants, it slows the slave motor,
preventing a bird’s nest. Because of the low torque produced by the slave
motor, a brake system is used to prevent wire overrun rather than tension.
The drag adjustment in the spindle is used simply to keep the wire slightly
taut, so it will not unspool while feeding wire.
The 24 VDC gun motor is controlled by a solid state speed control and a
pot located in the gun. The gun motor, potentiometer, and micro switch are
connected to the cabinet/control box via a control cable and an amphenol
connector. If this cable becomes damaged, a variety of symptoms can occur,
depending on which wire(s) break. To test, check each wire for continuity
and shorts.
With the increased torque rating in the current Prince XL Millermatic
Compatible motor, it now draws about twice as much current on start-up
as the original Prince motors P/N’s 211-0054 & 211-0056. Even though
the duration of start-up is very short, about 15msec, it is too much for the
standard 2A fuse to handle. For this reason, all 2A fuses in the motor
circuitry should be changed to a 3AG 4A fast blow 250V fuse. This new 4A
fuse is sufficient for use on all model welding guns on the wire feeders, while
still providing protection for the circuitry from any shorts in the motor or motor
leads.
This fuse change includes all Cobramatic, Cobramatic II and CobraMig
250/260, WC-1, Torpedo’s, and any other motor circuits powering Prince XL
Millermatic Compatible or Spool Guns.
Remember the micro switch in the gun activates both the 115 VAC or 42
VAC and 24 VDC circuits in the cabinet. Therefore, if the slave motor and
brake solenoid operate, but the gun does not, look more toward the 24 VDC
circuits, speed control, control cable, or the gun motor. If nothing operates,
look more toward the 115 VAC or 42 VAC input, micro switch leads, or micro
switch.