INSTALLATION INSTRUCTIONS

It is the responsibility of the installer of this air condi-

tioner system to ensure structural integrity of the RV

roof. Never create a low spot on the roof where water

will collect. Water standing around the air conditioner

may leak into the interior causing damage to the product

and the RV.

5. The 4-/4” x 4-/4” (±/8”) opening is part of the

return air system of the Air Conditioner and must be

finished in accordance with NFPA Standard 501C

Section 2.7.

6. Route a dedicated 2 VDC supply line (8-22 AWG)

from the RV’s converter or battery to the roof opening.

a. Wire must be fused at 3 Amps.

b. This supply line must be located in the front portion

of the 4-/4” (±/8”) opening.

c. Make sure that at least 5” of supply wire extends

into the roof opening.

d. In a multiple zone installation, this wiring is

required in only one of the 14-1/4” (±1/8”)

openings.

7. If a Remote Temperature Sensor is used, the connec-

tor end must be routed to the roof opening of the

system which it will control. Make sure that at least

5” of the sensor cable extends into the roof opening.

Refer to the Remote Sensor Instructions for details of

the installation.

8. If a furnace is to be controlled by the system, the two

15”

min.

3/4” MIN.

FRAME OPENINg SO IT WON’T COL-

LAPSE WHEN BOLTINg DOWN AIR

CONDITIONER

LEAVE ACCESS FOR POWER

SUPPLy WIRINg

furnace thermostat leads must be routed to the roof

opening of the air conditioner that will control it. Make

sure that at least 5” of the furnace thermostat wires

extend into the roof opening.

9. If an Energy Management System (load shed fea-

ture) is to be used with the control, two wires must

be routed to the roof opening of the zone to be

managed. The signal required for this function is

normally open relay contact. When the EMS calls for

the compressor to shut off, the relay contacts should

close. Make sure at least 5” of the EMS wires

extend into the roof opening.

0. Route a 4-conductor control cable from the

Comfort Control Center™ mounting position into

the 4-/4” (±/8”) roof opening. Make sure that at

least 5” of the wire extends into the roof opening and

6” extend from the wall at the mounting position of the

Comfort Control Center™.

. In the event that other Air Conditioners are installed

(additional zones) an additional 4-conductor control

cable must be routed to the other Air Conditioners.

Make sure that at least 5” of the wire extends into

the roof opening. (See Fig. 6)

2. If an automatic generator start kit (AGS) will be

installed, a 4-conductor control cable must be routed

from the last air conditioner to location of AGS kit.

Follow AGS kit instructions for installation.

4. DOMETIC COMFORT CONTROL

CENTER™ & CABLE INSTALLATION

A. LOCATION

. If the system is to be used WITHOUT a Remote

Temperature Sensor, the proper location of the

Comfort Control Center™ is very important to

ensure that it will provide a comfortable RV tempera-

ture. Observe the following rules when selecting a

location:

a. Locate the Comfort Control Center™ 54” above

the floor.

b. Install the Comfort Control Center™ on a partition,

not on an outside wall.

c. NEVER expose it to direct heat from lamps, sun

or other heat producing items.

d. Avoid locations close to doors that lead outside,

windows or adjoining outside walls.

e. Avoid locations close to supply registers and the

air from them.

2. If the system is to be used WITH a Remote Tem-

perature Sensor in ALL zones, the Comfort Control

Center may be mounted anywhere that is convenient

in the coach. Try to avoid hard to reach and hard to

see areas.

a. Refer to the instructions provided with the Re-

move Temperature Sensor for details of

installation.