Technical specifications fdm509 – Meinberg FDM509 User Manual
Page 14

14
Technical Specifications FDM509
INPUT SIGNALS: 10MHz oscillator clock (TTL level)
pulse per second, activ high (TTL level)
serial time string (RS232), 19200 baud, 8N1
(see "Format
of the Meinberg Standard Time String")
mains voltage, 70V... 270V, 45Hz ... 65Hz (protected with
200mA fuse, slow blowing)
OUTPUTS:
2 analog outputs: -2,5V ... 2,5V, resolution: 16 bit
fail output (TTL level)
overflow output (TTL level)
SERIAL
RS232 PORTS:
2 serial RS232 ports, COM1: 19200 baud, 8N1
COM0 configurable via DIL-switch:
Baudrate:
9600 or 19200 baud
Framing:
7E2 or 8N1
output and average once per second or once per minute
output string: one of two different formats selectable, see chap-
ter "Output String"
ACCURACY OF
MEASUREMENT: frequency:
accuracy of reference (10MHz) ±1mHz
time deviation:
accuracy of reference (PPS) ±1ms
CONNECTORS:
rear VG edge connector, mixed F/H, DIN 41612
Type F: 24 poles, type H: 7 poles
optional: mains socket in the front panel
POWER
REQUIREMENTS: +5V, @180mA
PHYSICAL
DIMENSIONS:
Eurocard, 100mm x 160mm, 1.5mm Epoxy
FRONT PANEL:
3U / 8HP (128mm high x 40.6mm wide), Aluminium
AMBIENT
TEMPERATURE: 0 ... 50°C
HUMIDITY:
max. 85 %
OPTIONS:
power line input via mains socket in the front panel
Hardware and software modifications accordding to customer
specification