Safety instructions for building-in equipment

This building-in equipment has been designed and tested in accordance with the

requirements of Standard IEC 950 "Safety of Information Technology Equipment,
including Electrical Business Equipment".

During installation of the building-in equipment in an end application (i.e. rack)
additional requirements in accordance with Standard IEC 950 have to be taken into
account.

o The building-in equipment is a class 1 - equipment and must be connected to an

earthed outlet (TN Power System).

o The building-in equipment has been evaluated for use in office environment

(pollution degree 2) and may be only used in this environment. For use in rooms
with a higher pollution degree more stringent requirements are applicable.

o The building-in equipment may not be opened.

o Protection against fire must be assured in the end application.

o The ventilation opening may not be covered.

o The equipment/building-in equipment was evaluated for use in a maximum

ambient temperature of 40 °C.

o For safe operation the building-in equipment must be protected by max 16 A

fuse in the power installation system.

o Disconnection of the equipment from mains is done by pulling the mains plug.

CE-Label

EN 60950

Safety of Information Technology Equipment,
including Electrical Business Equipment

Electromagnetic compatibility

EN50081-1

Electromagnetic compatibility (EMC). Generic emission
standard. Part 1: Residential, commercial and light industry

EN50082-2

Electromagnetic compatibility (EMC). Generic immunity
standard. Part 2: Industrial environment