2.4 OPERATION

After configuring the

Extender488s attaching the serial port or fiber optic cabling, plug the power

supply connector into the rear jack on the interface.

CAUTION

Never install the power s upply into the interface while it is connected to AC line
power. Failure to observe this caution may result in damage to the Extender488.
Only a supply with regulated +5 volt output should be used.

WARNING

The power supply provided with the interface is int ended for INDOOR USE
ONLY. Failure to observe this warning could res ult in equi pment failure,
personal injury or death.

After installing the power s upply connector into the interface, plug the power supply into the AC

line power. Place the rear panel power switch in the

ON [1] position. All front panel indicators should

light for a pproximately one second while the

Extender488 performs an i nternal ROM and R AM self

check. At the end of the power-on sequence, the ERROR LED should continue to blink, indicating that
communications with another extender has not been established. Now repeat the above procedure with the
second extender, and observe the same results. If any of the following LED conditions exist after power-
on, a failure has occurred.

SYMPTOM

FAILURE

All lights remain on

ROM test has failed

All lights blink continually

RAM test has failed

No LEDs blink

Power supply has failed

This manual is related to the following products: