beautypg.com

Specifications, Digital input / output, Counter – Measurement Computing USB-1024LS User Manual

Page 15: Power, Specifications -1, Digital input / output -1, Counter -1, Power -1

background image

Chapter 4

Specifications

Typical for 25 °C unless otherwise specified.
Specifications in italic text
are guaranteed by design.

Digital input / output

Table 1. Digital I/O specifications

Digital type

82C55

Number of I/O

24 (Port A0 through Port C7)

Configuration

2 banks of 8 and 2 banks of 4, or
3 banks of 8

Pull up/pull-down configuration

All pins pulled up to Vs via 47K resistors (default). Selection available for
pull down to ground. Hardware selectable via zero ohm resistor.

Input high voltage

2.0 V min, 5.5 V absolute max

Input low voltage

0.8 V max, –0.5 V absolute min

Output high voltage (IOH = -2.5 mA)

3.0 V min

Output low voltage (IOH = -2.5 mA)

0.4 V max

Power up / reset state

Input mode

Counter

Table 2. Counter specifications

Counter type

Event counter

Number of channels

1

Input source

CTR screw terminal

Input type

TTL, rising edge triggered

Resolution 32

bits

Schmidt trigger hysteresis

20 mV to 100 mV

Input leakage current

±1 µA

Maximum input frequency

1 MHz

High pulse width

500 ns min

Low pulse width

500 ns min

Input low voltage

0 V min, 1.0 V max

Input high voltage

4.0 V min, 15.0 V max

Power

Table 3. Power specifications

Parameter Conditions

Specification

Supply current (Note 1)

20 mA typ, 40 mA max

Connected to Self-Powered Hub

4.5 V min, 5.25 V max

+5V USB power available (Note 2)

Connected to Bus-Powered Hub

4.1 V min, 5.25 V max

Connected to Self-Powered Hub

460 mA max

Output Current (Note 3)

Connected to Bus-Powered Hub

60 mA max

Note 1:

This is the total current requirement for the USB-1024LS which includes up to 5mA for the
status LED.

4-1