beautypg.com

External pacer input/output – Measurement Computing USB-202 User Manual

Page 17

background image

USB-202 User's Guide

Specifications

17

External pacer input/output

Table 7. External pacer I/O specifications

Parameter

Specification

Terminal names

AICKI, AICKO

Terminal types

AICKI:

Input, active on rising edge

AICKO:

Output, power on default is 0 V, active on rising edge

Terminal descriptions

AICKI:

Receives pacer clock from external source

AICKO:

Outputs internal pacer clock

Input clock rate

100 kHz max

Clock pulse width

AICKI:

400 ns min

AICKO:

400 ns min

Input type

Schmitt trigger, 47 kΩ pull-down to ground

Schmitt trigger hysteresis

1.01 V typ
0.6 V min
1.5 V max

Input high voltage

2.43 V typ
1.9 V min
3.1 V max

Input low voltage

1.42 V typ
1.0 V min
2.0 V max

Input voltage limits

5.5V absolute max
-0.5V absolute min
0V recommended min

Output high voltage

4.4 V min (IOH = –50 µA)
3.80 V min (IOH = –8 mA)

Output low voltage

0.1 V max (IOL = 50 µA)
0.44 V max (IOL = 8 mA)

Output current

±8 mA max

This manual is related to the following products: