I7000_digitaloutreadback – Measurement Computing CB-NAP-7000P User Manual
Page 24
20
5.12 I7000_DigitalOutReadBack
z Description:
Read back the digital output value of CB-7000 series module.
z Syntax:
I7000_DigitalOutReadBack(WORD w7000[], float f7000[], char szSendTo7000[], char szReceiveFrom7000[])
z Input Parameter:
w7000: WORD Input/Output argument table
f7000: float Input/Output argument table
szSendTo7000: command string send to CB-7000
szReceiveFrom7000: result string read from CB-7000
z Return Value:
NoError: OK
others: Error code, refer to I7000.H
z W7000: WORD Input/Output Table
w7000[0] : RS-232 port number, 1/2/3/4
w7000[1] : module address, from 0x00 to 0xFF
w7000[2] : module ID, 0x7050/7060/7067/7042/7043/7044
w7000[3] : 0=checksum disable, 1=checksum enable
w7000[4] : TimeOut constant, normal=100
w7000[5] : 16-bit digital output data read back
w7000[6] : 0
:no save to szSendTo7000&szReceiveFrom7000
1
:szSendTo7000=command string send to CB-7000
:szReceiveFrom
7000=result string receive from CB-7000
z F7000:
Float Input/Output Table
void
w7000[0]=cPort; // port
w7000[1]=wAddr; // Address
w7000[2]=0x7053; // ID
w7000[3]=0; // CheckSum disable
w7000[4]=wTimeOut; // TimeOut constant
w7000[6]=1; // string debug
wRet=I7000_DigitalOutReadBack(w7000, f7000, szSend, szReceive);
// w7000[5] = digital output read back