16

5.8 I7000_AnalogOut


z Description:

Send the analog output command to CB-7000.

z Syntax:

I7000_AnalogOut(WORD w7000[], float f7000[], char szSendTo7000[], char szReceiveFrom7000[])

z Input Parameter:

w7000: WORD Input/Output argument table
f7000: float Input/Output argument table
szSendTo7000: command string send to CB-7000
szReceiveFrom7000: result string read from CB-7000

z Return Value:

NoError: OK
others: Error code, refer to I7000.H

z W7000: WORD Input/Output Table

w7000[0] : RS-232 port number, 1/2/3/4
w7000[1] : module address, from 0x00 to 0xFF

w7000[2] : module ID, 0x7021

w7000[3] : 0=checksum disable, 1=checksum enable
w7000[4] : TimeOut constant, normal=100
w7000[6] : 0

:no save to szSendTo7000&szReceiveFrom7000

1

:szSendTo7000=command string send to CB-7000

:szReceiveFrom

7000=result string receive from CB-7000

z F7000:

Float Input/Output Table

f7000[0] : analog output value


w7000[0]=cPort; // port
w7000[1]=wAddr; // Address
w7000[2]=0x7021; // ID
w7000[3]=0; // CheckSum disable
w7000[4]=wTimeOut; // TimeOut constant
w7000[6]=1; // string debug
f7000[0]=5.432; // DA output value
wRet=I7000_AnalogOut(w7000, f7000, szSend, szReceive);