HOOD EXHAUST DUCT

NOTE:

Total length must not exceed the equivalent of 140 Ft.

Recommended Standard Fittings

One 90 degree elbow (25 ft.)

=25 ft.

Wall cap (40 ft.)

=40 ft.

8 feet straight duct

= 8 ft.

Total length

=73 ft.

3-

1

/

4

” x 10” to 6” transition (5 ft.)= 5 ft.

Two 90 degree elbows (10 ft.)

=20 ft.

Wall cap (40 ft.)

=40 ft.

8 feet straight duct

= 8 ft.

Total length

=73 ft.

3-

1

/

4

x10” rectangular vent system

6” round vent system

6ft.

2ft.

3-

1

/

4

” x 10”

90° elbow

Wall cap

6ft.

2ft.

Transition

90° elbows

3-

1

/

4

” x 10” to 6” (5 ft.) 3-

1

/

4

” x 10” roof cap (24 ft.) 3-

1

/

4

” x 10” 90° elbow (25 ft.)

90° elbow (10 ft.)

45° elbow (5 ft.)

45° elbow (5 ft.)

3-

1

/

4

” x 10” flat elbow (10 ft.)

3-

1

/

4

” x 10” wall cap (40 ft.)

OTR-Installation-M1.fm Page 9 Wednesday, September 27, 2000 4:03 PM