9hood exhaust duct, 6ft. 2ft – Maytag MMV5100AAB Installation User Manual
Page 9
9
HOOD EXHAUST DUCT
NOTE:
Total length must not exceed the equivalent of 140 Ft.
Recommended Standard Fittings
One 90 degree elbow (25 ft.)
=25 ft.
Wall cap (40 ft.)
=40 ft.
8 feet straight duct
= 8 ft.
Total length
=73 ft.
3-
1
/
4
” x 10” to 6” transition (5 ft.)= 5 ft.
Two 90 degree elbows (10 ft.)
=20 ft.
Wall cap (40 ft.)
=40 ft.
8 feet straight duct
= 8 ft.
Total length
=73 ft.
3-
1
/
4
”
x10” rectangular vent system
6” round vent system
6ft.
2ft.
3-
1
/
4
” x 10”
90° elbow
Wall cap
6ft.
2ft.
Transition
90° elbows
3-
1
/
4
” x 10” to 6” (5 ft.) 3-
1
/
4
” x 10” roof cap (24 ft.) 3-
1
/
4
” x 10” 90° elbow (25 ft.)
90° elbow (10 ft.)
45° elbow (5 ft.)
45° elbow (5 ft.)
3-
1
/
4
” x 10” flat elbow (10 ft.)
3-
1
/
4
” x 10” wall cap (40 ft.)
OTR-Installation-M1.fm Page 9 Wednesday, September 27, 2000 4:03 PM