Alarm Responses
The security system can generate two levels of alarm: Warn Away - Soft
siren chirps and flashing parking lights.
The purpose of Warn-Away is to warn a would-be thief next to your
vehicle that the vehicle is protected, but in a manner that does not call
attention to it from more than a few feet away.
Full Alarm Trigger
Sounds the siren at maximum volume and flashes the parking lights.
The default duration of the Full Alarm is 30 seconds. This can be pro-
grammed to any duration from 30 to 60 seconds manually. Ask your
authorized dealer for details.
Warn-Away response is triggered by:
Lesser or lighter vibrations or impacts (detected by the Stinger
•
Doubleguard shock sensor)
Opening a door: the Progressive Door Trigger feature will sound
•
the Warn Away response, followed immediately by Full Alarm
Any attempt to start the car: the Progressive Ignition Trigger will
•
first sound the Warn Away response, followed immediately by Full
Alarm.
An optional Proximity Sensor (508D) triggered in the outer zone.
•
Full Alarm response is triggered by:
Heavier impact to the vehicle (detected by the Stinger Double-
•
Guard shock sensor).
Opening the trunk or hood (if connected).
•
Opening a door: the Progressive Door Trigger feature will first
•
sound the Warn-Away response, followed immediately by Full
Alarm.
An optional sensor, such as an optional Proximity Sensor triggered
•
in the inner zone.